ALUMINUM NEUTRAL BAR MEC (4)1/0-14 (9)6-14 (2) MTG T UR CSA

IL.NBAE-0409-2
Image
Availability of your Futech:
0
Total availability of Futech:
12
(some items may not be transferable)

Additional information :

Manufactured from high strength aluminum alloy Electro tin plated for low contact resistance Low contact resistance Application versatility Ensures reliability Additional Class Attributes Connection Mechanical Mounting Hole Type Thru Number of Conductors 1 Number of Mounting Holes 2 Number of Poles 1 Number of Ports Tap 9 Additional Technical Specifications Conductor Type Stranded Conductor Type Solid Dimensions Dimension G (IN) 1.133 Dimension G (mm) 28.7782 Drive Size Main NA Drive Type Main Slotted Height (IN) 0.729 Height BX (IN) 2.9 Height (mm) 18.5166 Length (IN) 4.609 Length (mm) 117.0686 Mounting Bolt/Stud Size (mm) 254 Mounting Hole Diameter (IN) 0.203 Mounting Hole Diameter (mm) 5.1562 Mounting Hole Position (IN) 4 & 12 Mounting Hole Spacing (IN) 2.344 Mounting Hole Spacing (mm) 59.5376 Weight (LB) 0.121 Weight BX (LB) 2.574 Width (IN) 0.375 Width BX (IN) 5.5 Width (mm) 9.525 Material and Finish Conductor Material Copper Conductor Material Aluminum Connector Finish Tin Insulation NA Material Aluminum Wire Binding Hardware Finish Zinc Clear Trivalent Chromate Wire Binding Hardware Material Steel Bolt and Screw Sizes Mounting Bolt/Stud Size #10 Number of Wire Binding Screws per Port 1 Wire Binding Screw Size 5/16 Wire Binding Torque 8 - 6 AWG = 25 Wire Binding Torque 10 - 14 AWG = 35 Wire Binding Torque 8 AWG = 40 Wire Binding Torque 4 - 6 AWG = 45 Wire Binding Torque 1/0 - 2 AWG = 50 Wire Binding Torque 10 - 14 AWG = 15 Color Color Silver Conductor Ranges Conductor Range AL Solid (Secondary, tap, load) 10 Sol - 14 Sol Conductor Range AL Stranded (Primary, run, main, line) 1/0 Str - 14 Str Conductor Range AL Stranded (Secondary, tap, load) 6 Str - 14 Str Conductor Range CU Solid (Primary, run, main, line) 10 Sol - 14 Sol Conductor Range CU Solid (Secondary, tap, load) 10 Sol - 14 Sol Conductor Range CU Stranded (Primary, run, main, line) 1/0 Str - 14 Str Conductor Range CU Stranded (Secondary, tap, load) 6 Str - 14 Str Conductor Range AL Solid (Primary, run, main, line) 10 Sol - 14 Sol Voltage Voltage Rating 35 kV Testing Standards CSA File Number LR-29601 CSA Standard C22.2 No. 65-03 Prop65 Compliance This product is in compliance with Prop65. It is not known to contain any chemicals associated with this regulation UL Control Number NA UL / CULUS Specification UL 486A/B Recognized UL / CULUS Specification UL 467 Listed UL File Number E6207 General Bag Quantity 1 Carton Quantity Description STD PACK QTY 20 Dual Rated Yes NEMA Code S-588-3 UPC Code 78366900580