TeSys island analog IO module, 2 analog inputs, 1 analog output. Connected to a TPRBC bus coupler it is used for advanced control functions (TeSys avatars). Two analog inputs can be configured for measurement of voltage (-10/+10V, 0/+10V), current (0-20mA, 4-20mA) or temperature probes (Ni, Pt, thermocouples). One analog output can be configured for driving voltage source (-10/+10V, 0/+10V) or current source (0-20mA, 4-20mA). Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh). Specifications Main Range TeSys Product name TeSys island Device short name TPRAN Product or Component Type Analog IO module device presentation IO module providing 2 analog inputs and 1 analog output Enabling advanced control functions in a TeSys island system Operational only when connected to a bus coupler TPRBC function of module Measurement of voltage, current or temperature on 2 configurable analog inputs Driving voltage or current source on 1 configurable analog output Product compatibility TPRBC bus coupler Analogue input number 2 isolated with common point Analogue input type Current 4...20 mA Current 0...20 mA Voltage 0...10 V Voltage - 10...10 V Temperature probe - 60...180 °C Ni 100 Temperature probe - 60...180 °C Ni 1000 Temperature probe -200...+850 °C Pt 100 Temperature probe - 200...600 °C Pt 1000 Thermocouple - 200...1000 °C thermocouple J Thermocouple - 200...1300 °C thermocouple K Thermocouple 0...1760 °C thermocouple R Thermocouple 0...1760 °C thermocouple S Thermocouple 0...1820 °C thermocouple B Thermocouple - 200...400 °C thermocouple T Thermocouple - 200...1300 °C thermocouple N Thermocouple - 200...800 °C thermocouple E Thermocouple 0...2315 °C thermocouple C Measurement accuracy +/- 0.1 % of full scale voltage 77 °F (25 °C) +/- 0.1 % of full scale current 77 °F (25 °C) +/- 0.1 % of full scale temperature probe 77 °F (25 °C) +/- 0.1 % of full scale in positive temperature range thermocouple 77 °F (25 °C) +/- 0.4 % of full scale in negative temperature range thermocouple 77 °F (25 °C) Analogue input resolution 15 bits + sign full scale Input impedance <= 50 Ohm current >= 1 MOhm voltage >= 1 MOhm thermocouple >= 1 MOhm temperature probe Analogue output number 1 isolated Analogue output type Current 4...20 mA Current 0...20 mA Voltage 0...10 V Voltage - 10...10 V Analogue output resolution 12 bits, 4...20 mA full scale 12 bits, 0...20 mA full scale 12 bits, 0...10 V full scale 11 bits + sign, - 10...10 V full scale Type of cable Twisted shielded pairs cable <98.43 ft (30 m) input/output Local signalling For DS (device status) 1 LED (green/red)