MINI CONTR W/24V COIL

TB.B7-30-01-01
Image
Availability of your Futech:
0
Total availability of Futech:
5
(some items may not be transferable)

Additional information :

The B7-30-01 mini contactor is a compact 3 pole contactor with 1 auxiliary contact and screw terminals. They are ideally suited for applications where reliability is a must and space is at a premium. Mini contactors are used in residential buldings, commercial buildings and industrial applications for the control of single or three-phase loads up to 5.5 kW (AC-3) and 20 A (AC-1) or switching of control signals. Further features are the silent coil, a switch position indication and the integrated possibility for rail or wall mounting. Technical Number of Poles: 3 Mini Contactor Type: Mini Contactor Rated Operational Voltage: Auxiliary Circuit 690 V AC Auxiliary Circuit 250 V DC Main Circuit 690 V AC Main Circuit 220 V DC Rated Frequency (f): Control Circuit 400 Hz Control Circuit 50 Hz Control Circuit 60 Hz Main Circuit 50 Hz Main Circuit 60 Hz Main Circuit DC Rated Impulse Withstand Voltage (Uimp): Auxiliary Circuit 6 kV Main Circuit 6 kV Rated Insulation Voltage (Ui): 690 V acc. to UL/CSA 600 V Number of Main Contacts NC: 0 Number of Main Contacts NO: 3 Rated Operational Current AC-1 (Ie): (220 / 240 V) 40 °C 20 A (220 / 240 V) 55 °C 16 A (380 / 440 V) 40 °C 20 A (380 / 440 V) 55 °C 16 A (690 V) 40 °C 6 A (690 V) 55 °C 6 A Rated Operational Power AC-3 (Pe): (230 V) Three Phase 3 kW (400 V) Three Phase 5.5 kW (500 V) Three Phase 5.5 kW (690 V) Three Phase, NO 3 kW Rated Short-time Withstand Current Low Voltage (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A Number of Auxiliary Contacts NC: 1 Number of Auxiliary Contacts NO: 0 Rated Operational Current AC-15 (Ie): (24 V) 4 A (120 V) 4 A (500 V) 2 A (220 / 240 V) 4 A (380 / 400 V) 3 A Rated Operational Current DC-13 (Ie): (24 V) 2.5 A (110 V) 0.7 A (220 / 240 V) 0.4 A Conventional Free-air Thermal Current (Ith): Main Circuit 20 A Rated Control Circuit Voltage (Uc): 24 V AC Coil Operating Limits: (acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at ? = 55 °C) Degree of Protection: Auxiliary Circuit Terminals IP20 Control Circuit Terminals IP20 Main Circuit Terminals IP20 Mechanical Durability: 10000000 cycle Minimum Switching Capacity: Auxiliary Circuit 17 V Auxiliary Circuit 5 mA Maximum Electrical Switching Frequency: (AC-1) 300 cycles per hour (AC-15) 600 cycles per hour (AC-3) 600 cycles per hour (DC-1) 600 cycles per hour (DC-13) 600 cycles per hour (DC-3) 600 cycles per hour Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 1 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² Flexible 1/2x 1 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 1 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² Flexible 1/2x 1 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 1 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 1 ... 2.5 mm² Flexible 1/2x 1 ... 2.5 mm² Rigid 1/2x 1 ... 4 mm² Wire Stripping Length: Auxiliary Circuit 9 mm Control Circuit 9 mm Main Circuit 9 mm Tightening Torque: Auxiliary Circuit 0.8 ... 1.1 N·m Control Circuit 0.8 ... 1.1 N·m Main Circuit 0.8 ... 1.1 N·m Recommended Screw Driver: M3 Pozidriv 1 Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 Power Loss: at Rated Operating Conditions AC-1 per Pole 1.4 W Standards: IEC/EN 60947-1 IEC/EN 60947-4-1 IEC/EN 60947-5-1 UL 60947-1 UL 60947-4-1

Amperage: 12A