DRAF ENCLOSED STR CONT VOLT 100-250

TB.DRAF16-13U
Image
Availability of your Futech:
0
Total availability of Futech:
4
(some items may not be transferable)

Additional information :

The DRAF16-13U is an enclosed Direct-On-Line starter with an AF contactor used for controlling 3-phase asynchronous motors up to 690 V AC. Each starter is delivered assembled and wired. It contains: • IP66 and type 4X plastic enclosure with double insulation, equiped with: - 1 green flush "I" ON button and 1 red protruding "O" OFF/RESET button - 4 cable inlets and outlets via knockouts: Inch cable inlet/outlet suitable for UL starter types. • 1 AF16-30-10-13 3-pole contactor with holding contact • DRAF..U with separate supply for UL starters type: AC control supply: 100-250V50/60HZ • 1 CB5-10 start contact block • 1 PE and 1 neutral terminal • TF42 thermal overload relay to be ordered separately and chosen according to motor's nominal current. Technical Coil Consumption: Holding at Max. Rated Control Circuit Voltage 60 Hz 100 V·A Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm² Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 1.5 mm² Rigid Solid 1/2x 1 ... 2.5 mm² Rigid Stranded 1/2x 1 ... 2.5 mm² Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 0.75 ... 6 mm² Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² Rigid Solid 1/2x 1 ... 4 mm² Rigid Stranded 1/2x 1 ... 6 mm² Housing Material: ABS Number of Auxiliary Contacts NC: 0 Number of Auxiliary Contacts NO: 1 Number of Main Contacts NC: 0 Number of Main Contacts NO: 3 Number of Poles: 3 Pollution Degree: 3 Rated Control Circuit Voltage (Uc): 50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Control Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 690 V acc. to IEC 60947-5-1 690 V Rated Operational Current AC-1 (Ie): (690 V) 40 °C 30 A (690 V) 60 °C 30 A (690 V) 70 °C 26 A Rated Operational Current AC-3 (Ie): (415 V) 60 °C 18 A (440 V) 60 °C 18 A (500 V) 60 °C 15 A (690 V) 60 °C 10.5 A (380 / 400 V) 60 °C 18 A (220 / 230 / 240 V) 60 °C 18 A Rated Operational Current AC-3e (Ie): (415 V) 60 °C 18 A (440 V) 60 °C 18 A (500 V) 60 °C 15 A (690 V) 60 °C 10.5 A (380 / 400 V) 60 °C 18 A (220 / 230 / 240 V) 60 °C 18 A Rated Operational Power AC-3 (Pe): (415 V) 9 kW (440 V) 9 kW (500 V) 9 kW (690 V) 9 kW (380 / 400 V) 7.5 kW (220 / 230 / 240 V) 4 kW Rated Operational Power AC-3e (Pe): (415 V) 9 kW (440 V) 9 kW (500 V) 9 kW (690 V) 9 kW (380 / 400 V) 7.5 kW (220 / 230 / 240 V) 4 kW Terminal Type: Screw Terminals