The GM40AVE-RD89 is a universal, electronic time switch designed for general purpose residential and commercial applications. The robust 40 A time control automatically detects the input voltage without the use of a DIP switch or selector pins. The time switch automatically selects any voltage between 120 VAC and 277 VAC. The mechanism is mounted in a compact UL Type 3R outdoor enclosure and can also be easily retrofitted into other Intermatic enclosure types. The time control features a DPDT switching configuration standard (i.e. two normally open and two normally closed contacts). Heavy-duty 40 A contact rating. Automatically adjusts voltages between 120-277 VAC. 24-Hour/7-day flexible scheduling. Power and status LED indicators. DPDT switching configuration (2 NO and 2 NC Contacts). 14 Setpoint programs. Manual override with load status indication. Self-recharging battery with back up protection up to 2500 hours. Type 3R outdoor enclosure with lockable hasp. To-the-minute accuracy. Aeration Air Movement & Ventilation Generator Exercising Refrigeration Merchandiser Septic Treatment Operation Mode 24 hour, 7 day Wiring Option Screw box lug Backup Protection Time 2500 Hours Backup Type Battery Battery Service Types Non-Replaceable CA Prop 65 Message This product is in compliance with Prop65 California Proposition 65 None Chemical Composition of the Battery Cell Ni-MH Color Gray Country of Origin (Intermatic) CHINA Daylight Savings Adjustment Manual Electrical Life 50,000 operations at full load Electronic Ballast Load Ratings NC Ranges 10 A, 277 VAC Electronic Ballast Load Ratings NO Ranges 30 A, 120 VAC; 20 A, 277 VAC EmbeddedBattery CBEP (Covered Battery Embedded Product) Enclosure Type Outdoor type 3R plastic Has Finger-Safe Terminals Yes Has Manual Override Status Indication Yes Material Plastic Minimum ON/OFF Times 1 min Motor Load Ratings NC Ranges 1 HP, 12 FLA, 30 LRA @ 120 VAC, 50/60 Hz; 2 HP, 10 FLA, 30 LRA @ 240 VAC, 50/60 Hz Motor Load Ratings NO Ranges 1 HP, 16 FLA, 96 LRA @ 120 VAC; 2 HP, 12 FLA, 52 LRA @ 208-277 VAC Number Of Circuits 2 Off Events 7 On Events 7 Other Certifications and Compatibilities Green Energy, Title 20 Resistive Load Ratings NC Ranges 30 A, 120-277 VAC Resistive Load Ratings NO Ranges 40 A, 120-277 VAC RoHS Certification Y Switch Type DPDT Total Events 14 Tungsten Incandescent Load Ratings NC Ranges 2 A, 120 VAC Tungsten Incandescent Load Ratings NO Ranges 15 A, 120 VAC UL Certification cULus Voltage Selection Type Auto-Voltage Warranty Period 1-Year limited Wire Size Max #8 AWG Operating Temperature Max (°C) 55 Operating Temperature Max (°F) 131 Operating Temperature Min (°C) -15 Operating Temperature Min (°F) 5 Product Depth (in) 3 Product Depth (mm) 76.2 Product Height (in) 8.875 Product Height (mm) 225.425 Product Width (in) 6.61 Product Width (mm) 167.9 Unit Carton Height (in) 9.28 Unit Carton Length (in) 6.91 Unit Carton Weight (lb) 1.83 Unit Carton Width (in) 3.16 Units Per Pallet 216