Manufactured from high strength 6061-T6 aluminum alloy Chamfered wire entry provides ease of installation Suitable for use with either copper or aluminum conductors Mounting hole spacing from side to side, hole to hole is 7/8 in Electro-tin plated provides low contact resistance Ensures reliability for copper or aluminum conductors Suitable for use in circuits rated 35 kV or less, proper high voltage spacing and insulation techniques must be used Application versatility 1-stud 17/64 in mounting hole Additional Class Attributes ConnectionMechanical Contains DE-OX®No Mounting Hole TypeThru Number of Conductors2 Number of Mounting Holes1 Number of Poles1 Number of Ports / Wireways2 Additional Technical Specifications Conductor TypeSolid Conductor TypeStranded Dimensions Dimension G (IN)0.422 Drive Size MainNA Drive Type MainSlotted Height (IN)0.794 Height BX (IN)2.25 Height (mm)20.1676 Length (IN)1.469 Length (mm)37.3126 Mounting Hole Diameter (IN)0.272 Mounting Hole Diameter (mm)6.9088 Mounting Hole Spacing (mm)0 Tang Length (IN)0.844 Tang Length (mm)21.4376 Tang Thickness (IN)0.187 Tang Thickness (mm)4.7498 Tang Width (IN)1.125 Tang Width (mm)28.575 Weight (LB)0.137 Weight BX (LB)1.8816 Width (IN)1.125 Width BX (IN)5 Width (mm)28.575 Material and Finish Conductor MaterialAluminum Conductor MaterialCopper Connector FinishTin InsulationNA MaterialAluminum Wire Binding Hardware FinishTin Wire Binding Hardware MaterialAluminum Bolt and Screw Sizes Mounting Bolt/Stud Size1/4 Number of Wire Binding Screws per Port1 Wire Binding Screw Size7/16 Wire Binding Torque2/0 - 2 AWG = 50 Wire Binding Torque10 - 14 AWG = 35 Wire Binding Torque8 AWG = 40 Wire Binding Torque4 - 6 AWG = 45 Environment and Temperature Temperature Rating90°C Color ColorSilver Conductor Ranges Conductor Range AL Solid (Secondary, tap, load)NA Conductor Range AL Stranded (Primary, run, main, line)1/0 Str - 14 Str Conductor Range AL Stranded (Secondary, tap, load)NA Conductor Range CU Solid (Primary, run, main, line)10 Sol - 14 Sol Conductor Range CU Solid (Secondary, tap, load)NA Conductor Range CU Stranded (Primary, run, main, line)1/0 Str - 14 Str Conductor Range CU Stranded (Secondary, tap, load)NA Conductor Range AL Solid (Primary, run, main, line)10 Sol - 14 Sol Wire CombinationsNA Voltage Voltage Rating35 kV Testing Standards CSA File NumberLR-29601 CSA StandardC22.2 No. 65-03 Prop65 ComplianceThis product is in compliance with Prop65. It is not known to contain any chemicals associated with this regulation ROHS IndicatorIND UL Control Number453G UL / CULUS SpecificationUL 467 Listed UL / CULUS SpecificationUL 486A/B Listed UL File NumberE6207 General Bag Quantity1 Carton Quantity DescriptionSTD PACK QTY 12 Direct BurialNo Dual RatedYes NEMA CodeS-588-3 UPC Code78366900066