Altivar HVAC ATH200 range is an offer of variable speed drives designed for HVAC Original Equipment Manufacturers (OEMs) to supply asynchronous and synchronous motors. With a degree of protection IP20, ATH230 is suitable for control panel mounting. It supplies 4kW/5HP motors at a rated voltage from 525 to 600V. Its robust design with IEC 60721-3-3 class 3C3 coated printed circuit boards allows to extend machine availability in harsh environmental conditions, such as ambient temperatures of up to 60°C, without the need of additional cooling. Its compact design and native features like Safe Torque Off, and A2L certification optimize the control panel and increase competitiveness. HVAC and programmable logic functions are integrated to simplify the automation system. ATH200 has native Modbus, BACnet MS/TP serial link, and BACnet/IP connectivity with an optional communication module. Dimensions are 140mm (width), 158mm (depth), 184mm (height) and it weighs 2.5kg. ATH230 uses plastic with more than 20% bio-based content, and aluminum is ASI-certified.
It complies with IEC/EN 81800-5-1 and IEC/EN 61800-3 and has received CE, cULus, UKCA, EAC, KC, and ATEX certifications. Mounting accessories and external options, such as line chokes, motor chokes, and additional EMC filters, are available for Altivar HVAC ATH200 drives. The packaging is made with recycled cardboard and contains no single-use plastic. It is designed to be mounted in a vertical position (+/- 10 °) on a panel, using 4 fixing holes. The embedded features and ATH200 design combine the competitiveness of compact HVAC machines with reliability, efficiency, and environmental sustainability. ATH230 delivers compact solutions without compromising on thermal behavior, to optimize the HVAC control panel design while providing high efficiency and reliability.
Specifications
Main
Range of product
Altivar HVAC ATH200
Product specific application
HVAC
Product or component type
Variable speed drive
Variant
Standard version
Device short name
ATH230
Product destination
Asynchronous motors
Synchronous motors
Mounting mode
Cabinet mount
IP degree of protection
IP20
Network number of phases
3 phases
[Us] rated supply voltage
525...600 V - 15...10 %
Relative symmetric mains voltage tolerance
10 %
Supply frequency
50...60 Hz - 5...5 %
Relative symmetric network frequency tolerance
5 %
Nominal output current
6.1 A
Maximum transient current
6.8 A
Motor power kW
4 kW
Motor power hp
5 hp
Safety function
STO (safe torque off)
Safety level
SIL 3 conforming to IEC 61508
PL = e conforming to ISO 13849-1
EMC filter
Without EMC filter
Communication port protocol
Modbus serial
BACnet MS/TP
Option card
Communication module for BACnet IP
Complementary
Apparent power
6.0 kVA at 600 V
Power dissipation in W
96 W
Discrete input number
7
Discrete input type
STO safe torque off, 24 V DC, impedance: 1.5 kOhm
DI1...DI6 logic inputs, 24 V DC (30 V)
DI5 programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
Discrete input logic
Positive logic (source)
Negative logic (sink)
[Us] rated supply voltage
24 V for DC
Discrete output number
1
Discrete output type
Open collector DQ+ 0…1 kHz 30 V DC 100 mA
Open collector DQ- 0…1 kHz 30 V DC 100 mA
Analogue input number
3
Analogue input type
AI1 voltage: 0...10 V DC, impedance: 30 kOhm, resolution 10 bits
AI2 bipolar differential voltage: +/- 10 V DC, impedance: 30 kOhm, resolution 10 bits
AI3 current: 0...20 mA (or 4-20 mA, x-20 mA, 20-x mA or other patterns by configuration), impedance: 250 Ohm, resolution 10 bits
Analogue output number
1
Analogue output type
Software-configurable current AQ1: 0...20 mA impedance 800 Ohm, resolution 10 bits
Software-configurable voltage AQ1: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Relay output number
2
Relay output type
Configurable relay logic R1A 1 NO electrical durability 100000 cycles
Configurable relay logic R1B 1 NC electrical durability 100000 cycles
Configurable relay logic R1C
Configurable relay logic R2A 1 NO electrical durability 100000 cycles
Configurable relay logic R2C
Maximum switching current
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1A, R1B, R1C on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1A, R1B, R1C, R2A, R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2A, R2C on resistive load, cos phi = 1: 5 A at 30 V DC
Minimum switching current
Relay output R1A, R1B, R1C, R2A, R2C: 5 mA at 24 V DC
Physical interface
2-wire RS 485
Connector type
RJ45
Method of access
Server Modbus serial
Subordinate BACnet MS/TP
Transmission rate
4800 bps, 9600 bps, 19200 bps, 38.4 Kbps
9.6, 19.2, 38.4, 76.8 kbit/s
Transmission frame
RTU
MS/TP
Number of addresses
0…247
0…127
Data format
8 bits, configurable odd, even or no parity 1or 2 stop
Type of polarization
No impedance
Line current
6.5 A at 525 V
5.8 A at 600 V
Prospective line Isc
5 kA
Output frequency
0.599 kHz
Output voltage
<= power supply voltage
Switching frequency
2...16 kHz adjustable
4...16 kHz with derating
nominal switching frequency
4 kHz
4 quadrant operation possible
True
Asynchronous motor control profile
Voltage/frequency ratio, 5 points
Flux vector control without sensor, standard
Voltage/frequency ratio - Energy Saving, quadratic U/f
Flux vector control without sensor - Energy Saving
Voltage/frequency ratio, 2 points
Synchronous motor control profile
Vector control without sensor
Acceleration and deceleration ramps
Linear
U
S
CUS
Ramp switching
Acceleration/deceleration ramp adaptation
Acceleration/deceleration automatic stop with DC injection
Motor slip compensation
Automatic whatever the load
Adjustable 0...300 %
Not available in voltage/frequency ratio (2 or 5 points)
Braking to standstill
By DC injection
Brake chopper integrated
True
Standards
IEC 61800-5-1
IEC 61800-3
UL 508C
IEC 61800-3 environment 1 category C2
IEC 61800-3 environments 2 category C3
IEC 60721-3
IEC 61508
IEC 13849-1
Product certifications
CULus
CE
UKCA
KC
EAC
ATEX
RCM
Marking
CULus
CE
UKCA
KC
EAC
ATEX
RCM
With safety function Safe torque off (STO)
True
Protection type
Line supply phase loss: drive
Motor phase loss: motor
Line supply overvoltage and undervoltage: drive
Overheating protection: drive
Overload: motor
With PTC probes: motor
Short-circuit between motor phases: drive
Overcurrent between output phases and earth: drive
Width
140 mm
Height
184 mm
Depth
158 mm
Product weight
2.5 kg
Function available
Fire mode
Run permissive
PID controller
Additional PID
Damper control
Underload detection for broken belt
Environment
Pollution degree
2
Operating altitude
<= 1000 m without derating
1000...3000 m with current derating 1 % per 100 m
Operating position
Vertical +/- 10 degree
Electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Environmental class (during operation)
Class 3C3 according to IEC 60721-3-3
Class 3S2 according to IEC 60721-3-3
Maximum acceleration under shock impact (during operation)
150 m/s² at 11 ms
Maximum acceleration under vibrational stress (during operation)
10 m/s² at 13...200 Hz
Relative humidity
5…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Volume of cooling air
37.7 m3/h
Overvoltage category
III
Noise level
52 dB
Ambient air transport temperature
-25…70 °C
Ambient air temperature for operation
-10…50 °C without derating
50…60 °C with derating factor
Ambient air temperature for storage
-25…70 °C